CHEMICAL RESISTANT BRICK PROPERTIES:

Khodiyar has been manufacturing chemical resistant brick and tiles since 1995, for 2 decades khodiyar has continuous made improvement in quality of brick and tiles manufacturing.

KCIPL owns 3 tunnel kilns and 6 vacuum extrusion machines makes the chemical resistant brick properties superior than other players in india.

KCIPL Chemical Resistant Brick Properties – Specification

  • Khodiyar acid/alkali resistant bricks comply with ASTM C-279 with type II and III specification.
  • It also complies with DIN EN 993-16 and IS 4860 with class I specification where minimum water absorption and maximum acid resistance is required.

Physical and Chemical Requirements of Chemical Resistant Brick, ASTM C-279

DesignationModulus of Rupture

(Brick or Tile Flatwise)min, PSI

(MPa)

Average of 5 Brick or Tile

Water Absorption Maximum %, by

2 Hr Boiling Test

Average of 5 Brick or Tile

H2SO4 Solubility

Maximum %

Weight Loss

Average of 5 Brick or Tile

LowIndividualHighIndividual
Type I1250 (8.6)1000 (6.9)6.07.020
Type II1250 (8.6)1000 (6.9)4.05.012
Type III1250 (8.6)1000 (6.9)1.01.58

Physical and Chemical Requirements of Chemical Resistant Brick, as per IS 4860

DesignationWater Absorption

Maximum %, by

2 Hr Boiling Test

Flexural Strength ,

Kg/Cm2

Minimum

Compressive Strength ,

Kg/Cm2

Minimum

H2SO4 Solubility

Maximum %

Weight Loss

Resistant to Wear,

Maximum

Class I21007001.5175
Class II4705004175

Khodiyar Acid and Chemical Resistant Brick Properties:

CharacteristicFireclayRed ShaleTest Standard
Bulk Density, lbs/ft32.25   to 2.302.30   to 2.35ASTM C-20
Water Absorption, %0.1   to 1.80.1   to 1.5IS 4860:1968
Apparent Porosity, %9.05   to 10.144.3   to 5.45ASTM C-20
Acid Solubility (H2SO4), Loss in Mass,%6.1   to 6.87.1   to 7.8ASTM C-279
Modulus of Rupture, MPa14.628.6ASTM C-67
Compressive Strength, PSI21447   to 2275722411   to 23125ASTM C-67
Abrasion Resistant , Volume in mm371   to 9669   to 85EN 102
Surface Hardness, MOHS Scale77
Thermal Conductivity, BTU-in/hr-ft²-°F6.94   to 7.127.1   to 8.9ASTM C-236
Thermal Expansion Coefficient,in/in/°Fx10-62.6   to 2.83.1   to 4.6EN 103

*Although we have no reason to doubt the accuracy of the data presented, Khodiyar ceramics (I) Pvt Ltd.. offers this information for comparison only, and disclaims any and all liability from error, omissions or inaccuracies, such that it does not constitute a warranty or representation for which we shall assume legal responsibility.


References:

  • Corrosion and Chemically Resistant Masonry Materials handbook by Walter Lee Sheppard, Jr., P.E.B. Chem., M.S.C.C.R.M., Inc. 1988
  • CSIR-Central Glass and Ceramics Research Institute. ( A unit of council of scientific and Industrial research)
  • Aglow Quality Control Laboratory Pvt Ltd. ( NABL Accredited Laboratory )

RequestFree Quote